<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Harpell Associates Inc. &#187; head | Harpell Associates Inc.</title>
	<atom:link href="http://www.harpell.ca/tag/head/feed" rel="self" type="application/rss+xml" />
	<link>http://www.harpell.ca</link>
	<description>Specializing in Diagnostic Imaging, Nuclear Medicine, and Radiation Therapy</description>
	<lastBuildDate>Fri, 13 Jan 2012 16:54:38 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Nucline X-Ring/4R (HR)</title>
		<link>http://www.harpell.ca/manufacturer/mediso/nucline-x-ring4r-hr</link>
		<comments>http://www.harpell.ca/manufacturer/mediso/nucline-x-ring4r-hr#comments</comments>
		<pubDate>Sun, 21 Feb 2010 21:43:36 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Mediso]]></category>
		<category><![CDATA[brain]]></category>
		<category><![CDATA[gamma camera]]></category>
		<category><![CDATA[head]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/?p=3963</guid>
		<description><![CDATA[<p>4-Head <span class="caps">SPECT</span>/PET Imaging System Dedicated for Brain, Pediatric, Small Animal, etc. Studies</p>]]></description>
			<content:encoded><![CDATA[<p>Hyper resolution four-head gamma camera for dedicated <span class="caps">SPECT</span>/PET for brain, newborn babies and small animal imaging with multiplied patient throughput</p>
<ul>
<li>240 <span class="caps">PMT</span> (HR model) </li>
<li>18FDG/PET imaging (optional) </li>
<li>maintenance-free mechanical gantry </li>
<li>4 pcs <span class="caps">PET</span>-based full digital <span class="caps">SFOV</span> detectors </li>
<li>multi segment continous acquisition (optional) </li>
<li>intrinsic spatial resolution <span class="caps">FWHM</span> &lt;= 2.3 mm (HR model) </li>
<li><span class="caps">FOV</span>: 230&#215;215mm </li>
<li>Energy range: 40-200 keV (40-600 keV with coincidence package) </li>
<li>Intrinsic energy resolution for 99mTc: 9.7%</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/mediso/nucline-x-ring4r-hr/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Served from: www.harpell.ca @ 2012-02-06 06:07:06 -->
