<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Harpell Associates Inc. &#187; area-monitor | Harpell Associates Inc.</title>
	<atom:link href="http://www.harpell.ca/tag/area-monitor/feed" rel="self" type="application/rss+xml" />
	<link>http://www.harpell.ca</link>
	<description>Specializing in Diagnostic Imaging, Nuclear Medicine, and Radiation Therapy</description>
	<lastBuildDate>Fri, 13 Jan 2012 16:54:38 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>area Monitor / Frisker Count Rate Meter</title>
		<link>http://www.harpell.ca/manufacturer/fluke/area-monitor-frisker-count-rate-meter</link>
		<comments>http://www.harpell.ca/manufacturer/fluke/area-monitor-frisker-count-rate-meter#comments</comments>
		<pubDate>Thu, 10 Dec 2009 01:08:51 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Fluke]]></category>
		<category><![CDATA[area-monitor]]></category>
		<category><![CDATA[frisker]]></category>
		<category><![CDATA[meter]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/general/area-monitor-frisker-count-rate-meter</guid>
		<description><![CDATA[<p>Depending on probe selection, the Model 190F detects alpha, beta, gamma, neutron, or x-ray radiation within an operating range of 1 &#956;R/h to 1 R/h or 1 CPM to 1,000,000 CPM.</p>]]></description>
			<content:encoded><![CDATA[<p>The Model 190F Area Monitor/Frisker Count Rate Meter is compatible with GM detectors, neutron probes, proportional counters, and scintillation probes operating from 300 to 1300 volts. Depending on probe selection, the Model 190F detects alpha, beta, gamma, neutron, or x-ray radiation within an operating range of 1 &mu;R/h to 1 R/h or 1 CPM to 1,000,000 CPM. The unit is available with either an MHV or a BNC connector, to provide the user with versatility in probe selection. Visual indication of selected parameters, as well as measured values, are displayed on the analog/digital display. The Model 190F Area Monitor/Frisker Count Rate Meter, with purchased probe, is shipped calibrated and ready-to-use. </p>
<p>Applications<br />
The Model 190F Area Monitor/Frisker Count Rate Meter is an easy to use instrument with error-free visual indication and auto-ranging. This instrument is designed to meet the high technology requirements of Health Physics, Medical Physics, and Non-Destructive Testing applications.</p>
<p>Features</p>
<ul>
<li>Adjustable Alarm </li>
<li>Backlit analog/digital display </li>
<li>Interchangeable probe adapter module </li>
<li>Multiple probe use </li>
<li>Redundant power supply </li>
<li>Available in SI units</li>
</ul>
<p>LCD display readout</p>
<ul>
<li>2.6 in wide (6.6 cm) x 2.0 in high (5.1 cm) </li>
<li>Analog scale has fifty-one elements arranged in a radius arc. Each element represents 2% of full scale. Scale markings are 0, 2, 4, 6, 8 and 10. Scale length is 2.2 in (5.6 cm) </li>
<li>Scale multiplier is 0.0001 to 1 million, dependent on probe selection and the activated units </li>
<li>16-character alphanumeric display shows digitized average of the bar graph value. It displays operational units such as radiation unit changes, response time changes, data and labels</li>
</ul>
<p>Pushbutton controls</p>
<ul>
<li>Light &#8211; Activates a background light for a preset or indefinite amount of time </li>
<li>Mode &#8211; Rolls through and displays the available units for the selected mode of operation </li>
<li>Log &#8211; Enters and sequentially labels the displayed data into a data log </li>
<li>Rate/Integ &#8211; Allows the user to select the mode of display </li>
<li>Resp &#8211; Time Rolls through and displays available response times (3, 6, 12 and 24 seconds) for user selection </li>
<li>Audio &#8211; Allows the user to turn the audio indicator on or off</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/fluke/area-monitor-frisker-count-rate-meter/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Digital Smart Detector area Monitor</title>
		<link>http://www.harpell.ca/manufacturer/fluke/digital-smart-detector-area-monitor</link>
		<comments>http://www.harpell.ca/manufacturer/fluke/digital-smart-detector-area-monitor#comments</comments>
		<pubDate>Thu, 10 Dec 2009 01:08:51 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Fluke]]></category>
		<category><![CDATA[area-monitor]]></category>
		<category><![CDATA[radiation-detection]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/general/digital-smart-detector-area-monitor</guid>
		<description><![CDATA[<p>The Model 1060AM is a versatile smart radiation detector designed for reliable, continuous area monitoring applications.</p>]]></description>
			<content:encoded><![CDATA[<p>The Model 1060AM is a versatile smart radiation detector designed for reliable, continuous area monitoring applications. The unit collects, interprets, analyzes, and communicates radiation measurement data. It is available in low, medium, and high range versions employing internal Geiger-Mueller (GM) detectors. The MHV version accommodates a wide variety of external GM probes. Circuitry that detects pulse pileup conditions in a high radiation field is employed to prevent erroneous readings.<br />
The Model 1060AM is suitable for stand-alone operation or in a network environment employing multiple channels, communicating via an RS-485 interface to a main computer system. WIN1060 PC applications program provides the ability to display multiple channels, to maintain both alarm and measurement history, and to access to system configuration options. An optional remote display, consisting of a visual alarm indicator and a logarithmic meter corresponding to the detector range, is available. </p>
<p>Applications<br />
The Model 1060AM is available in multiple versions supporting a wide range of monitoring applications found in medical facilities and facilities with radioisotope sources. In addition, the Model 1060AM provides an EMI shielded watertight National Electrical Manufacturers&#8217; Association (NEMA&reg;) enclosure that is CE marked. The Model 1060AM provides two RS-485 connectors to simplify connections between multiple units. A remote display with alarm lamp is available for each version. </p>
<p>Features</p>
<ul>
<li>Self contained, reliable, continuous area monitors </li>
<li>Wide range of applications in <span class="caps">NEMA 4</span> Enclosure </li>
<li>RS-485 interface for multi-drop applications </li>
<li>Optional <span class="caps">WIN 1060</span> Windows&reg; Applications Software monitors up to 30 channels </li>
<li>Custom configurations available </li>
<li>16-bit embedded controller </li>
<li>Optional remote display with alarm indicator</li>
<li>Available in 4 operating ranges </li>
<li><span class="caps">MHV</span> version for external probe </li>
<li>All versions available in SI units </li>
<li>Simple installation and setup</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/fluke/digital-smart-detector-area-monitor/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PRIMaLERT 35 area Radiation Monitor</title>
		<link>http://www.harpell.ca/manufacturer/fluke/primalert-35-area-radiation-monitor</link>
		<comments>http://www.harpell.ca/manufacturer/fluke/primalert-35-area-radiation-monitor#comments</comments>
		<pubDate>Thu, 10 Dec 2009 01:08:51 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Fluke]]></category>
		<category><![CDATA[area-monitor]]></category>
		<category><![CDATA[radiation-detection]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/general/primalert-35-area-radiation-monitor</guid>
		<description><![CDATA[<p>The PRIMALERT 35 Area Radiation Monitor contains an energy-compensated GM detector and utilizes six range indicators that can clearly display an increase or decrease in radiation levels.</p>]]></description>
			<content:encoded><![CDATA[<p>Six range indicators (1, 2, 4, 8, 16, and 32 mR/hr) clearly display an increase or decrease in radiation levels. The alarm can be set at any of the six levels by a front panel, screwdriver-adjustable control. Both the visible and audible alarms, or just the visible alarm, can also be set from this panel. The light for each level goes on when the radiation intensity reaches that level, and goes out when the rate drops below the level. This permits instant radiation-level recognition not readily distinguishable on meter-type instruments. </p>
<p>When the preset level is exceeded, personnel are alerted by bright flashing red lights (visible over a 180&deg; field) and a loud intermittent audio signal. The alarms stop automatically when the radiation level falls below the preset value. A front-panel switch permits the selection of both the visible and audible alarms or just the visible alarm. </p>
<p>Fail-safe operation is assured by a light which continuously indicates background radiation and provides visual proof that the unit is functioning. The monitor will not jam or show false readings in high radiation fields. The Primalert 35 contains an energy-compensated GM detector, and features a convenient, automatic alarm reset. A mounting bracket and a 110 volt AC adapter/power converter are also included. The optional Primalarm Remote Alarm provides the same audible and visible signals as the Primalert 35, up to 100 feet from the monitor. </p>
<p>Features</p>
<ul>
<li>Provides continuous visual indication of radiation levels and produces audible and/or visual alarms at any of six presettable radiation levels </li>
<li>Assures reliable, continuous monitoring wherever radioactive materials are present </li>
<li>Displays the radiation level in bright color-coded lights </li>
<li>Emits audible and/or visible signals whenever the gamma radiation exceeds a user-preset alarm level</li>
<li>Optional Primalarm Remote Alarm, which functions up to 100 feet from monitor</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/fluke/primalert-35-area-radiation-monitor/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PRIMaLERT Digital area Monitor</title>
		<link>http://www.harpell.ca/manufacturer/fluke/primalert-digital-area-monitor</link>
		<comments>http://www.harpell.ca/manufacturer/fluke/primalert-digital-area-monitor#comments</comments>
		<pubDate>Thu, 10 Dec 2009 01:08:51 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Fluke]]></category>
		<category><![CDATA[area-monitor]]></category>
		<category><![CDATA[radiation-detection]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/general/primalert-digital-area-monitor</guid>
		<description><![CDATA[<p>PRIMALERT Digital Area Monitor with internal energy compensated GM detector (0.1 mR/hr to 1 R/hr or 1 mR/hr to 4 R/hr)</p>]]></description>
			<content:encoded><![CDATA[<p>The PRIMALERT Digital Area Monitors are designed for a wide range of radiation area monitoring applications. They are completely self-contained units with energy compensated GM detectors, AC powered with internal battery backup and have user settable low and high alarms. An optional remote alarm is available for added security. </p>
<p>Applications<br />
The PRIMALERT Digital Area Monitors can be used wherever there is a need to detect and warn personnel of increasing radiation levels and to control the exposure of personnel to gamma radiation. The versatility of the PRIM ALERT allows it to be used from industrial applications to medical settings. </p>
<p>Features</p>
<ul>
<li>Key Features </li>
<li><span class="caps">LED</span> digital display </li>
<li>Low and High alarm indicators </li>
<li>Programmable alarm indicator </li>
<li>Optional remote </li>
<li>Detector Fail indicator </li>
<li>Battery backup </li>
<li>Data output/RS-232 </li>
<li>Two configurations available with internal energy compensated GM detectors:
<ul>
<li>mR/hr to 1 R/hr (05-443) </li>
<li>1 mR/hr to 4 R/hr (05-444)</li>
</ul>
</li>
<li>Simple installation and setup </li>
<li>Anti-jam circuitry prevents erroneous readings at tube saturation </li>
<li>Calibration controls easily accessed through front panel</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/fluke/primalert-digital-area-monitor/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PRIMaLERT Digital Doorway Monitor</title>
		<link>http://www.harpell.ca/manufacturer/fluke/primalert-digital-doorway-monitor</link>
		<comments>http://www.harpell.ca/manufacturer/fluke/primalert-digital-doorway-monitor#comments</comments>
		<pubDate>Thu, 10 Dec 2009 01:08:51 +0000</pubDate>
		<dc:creator>harpell</dc:creator>
				<category><![CDATA[Fluke]]></category>
		<category><![CDATA[area-monitor]]></category>
		<category><![CDATA[doorway]]></category>
		<category><![CDATA[radiation-detection]]></category>
		<category><![CDATA[waste]]></category>

		<guid isPermaLink="false">http://www.harpell.ca/general/primalert-digital-doorway-monitor</guid>
		<description><![CDATA[<p>The Model 05-450 Digital Doorway Monitor is a highly sensitive gamma radiation detection system designed to detect low levels of gamma radiation.</p>]]></description>
			<content:encoded><![CDATA[<p>The Model 05-450 Digital Doorway Monitor is a highly sensitive gamma radiation detection system designed to detect low levels of gamma radiation. </p>
<p>The system consists of a digital monitor, 2 shielded NaI (Tl) scintillation detectors with NEMA enclosures, associated cabling and a 10 &mu;Ci 137Cs check source. The system is AC powered with internal battery backup and user selectable alarm settings. </p>
<p>Applications<br />
The highly sensitive shielded scintillation detectors of the Model 05-450 Digital Doorway Monitor make this an ideal system to detect and alarm when low levels of gamma radiation pass through a doorway. Your Radiation Safety Officer (RSO) will find it ideal as a monitor mounted on the doorway for hospital entrances, emergency rooms, laundry rooms, waste disposal chutes, nuclear medicine labs and procedure rooms and any other area of the hospital where radiation contamination could be a concern. </p>
<p>Features</p>
<ul>
<li>Highly sensitive lead shielded NaI (Tl) scintillators </li>
<li><span class="caps">LED</span> digital display </li>
<li>Battery backup</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.harpell.ca/manufacturer/fluke/primalert-digital-doorway-monitor/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Served from: www.harpell.ca @ 2012-02-07 07:19:23 -->