A dedicated System when you need a small and truly portable solution for service work on fluoroscopic machines and only a sensitive dose range is needed.

Unfors FLUorO X-ray System 40
 
  • Features
  • Specifications
  • Options
  • Parts
  • Image Gallery

Features

Unfors R/F X-ray System 40 is a dedicated System when you need a small and truly portable solution for service work on fluoroscopic machines and only a sensitive dose range is needed. The Unfors Mult-O-Meter 514L measures kVp, dose, rate, dose/frame and time simultaneously with the most sensitive detectors Unfors offer. By means of the Dose/Frame feature it is possible to easily check machines with pulsed fluoroscopy capabilities.

Unfors Mult-O-Meter 514L with external detector for kVp FLUORO, Dose FLUORO, Rate FLUORO, Time, Dose/Frame, IR Link and Extended Functions

Specifications

kVp FLUORO Range (auto): 45 – 155 kVp

Minimum exposure: 1.5 mA at 70 kVp, 50 cm

Dose FLUORO Range (auto): 100 nGy – 9999 Gy, (11 µR – 9999 R)

Energy dependence: < 5 % at 2.5 mm Al, (50 – 150 kVp)

Rate FLUORO Range (auto): 100 nGy/s – 0.5 mGy/s, (0.7 mR/min – 3.5 R/min)

Energy dependence: < 5 % at 2.5 mm Al, (50 – 150 kVp)

Time Range (auto): 1 ms – 9999 s measured with the trigger detector

Inaccuracy: 0.5 % or 3 digits

Dose/Frame Range (auto): 200 nGy – 9999 Gy, (23 mR – 9999 R)

Minimum pulses/s: 10

Minimum pulse width: 1 ms

Extended functions Normalization of dose

Dose reproducibility

mAs linearity

Simplified HVL

Time corresponding to the 75 % triglevel of kVp waveform

kVp with a 5, 50, 150 ms delay

IR Link

Equipped with an infrared interface for transmission of measured data to a

PC. The IR receiver connected to the serial port of a PC, receives the

measured data. For data collection and calculations, the Unfors Excel Add-in

software is available for user customized reports.

Unfors DAQ-10 Software – needs.

Operating system Windows 98/ME, Windows 2000, Windows XP.

Microsoft Excel Office 97, 2000 and XP

Pen detector

holder Extendable holder for Unfors Mult-O-Meter external detectors for

easy positioning on I.I.’s, in buckys etc.

Options

1503010 Unfors Mult-O-Meter 704 SO (mA, mAs, Time)

1503011 Unfors Mult-O-Meter 714 SO (mAs)

1503012 Unfors Mult-O-Meter 603 SO (Dose CT, Time)

1901043 HVL Kit

Parts

Unfors Mult-O-Meter 514L

Ext. detector 1: kVp FLUORO, Dose FLUORO, Rate FLUORO, Time, incl. EF, IR link and Dose/Frame

Unfors DAQ-10 Kit

Pen detector holder

Unfors QA Case 2

Image Gallery

Click on a thumbnail below to view full size.

  • Default Image

Posted in Unfors | Tagged 514l, assurance, control, detection, diagnostic, dose, fluoro, fluoroscopy, frame, hvl, kvp, qa, qc, quality, rate, system-40, time, Unfors, waveform, x-ray, xray

Next »
  • Manufacturers
  • Technologies

Featured Manufacturers

  • Biodex
  • Bionix
  • Capintec
  • Diacor
  • Exini
  • Fluke
  • International Specialty Products
  • IZI Medical Products
  • Mediso
  • PTW
  • Topex
  • Unfors
  • Vision RT
  • View all...

Technologies

  • Nuclear Medicine
  • Radiology
  • Radiation Therapy

Copyright © 2012 Harpell Associates Inc..

  • Home
  • About
  • News
  • Contact