0.1 Liter Radiation Monitoring Chamber Type 32001

Cylindrical Al chamber for stationary and mobile radiation monitoring of high level gamma radiation

0.1 Liter Radiation Monitoring Chamber Type 32001
 

Features

  • Vented sensitive volume of 102 cm3 Suitable as radiation monitoring chamber
  • Rigid construction for wall mounting
  • Gamma energy range 80 keV to 1.3 MeV

The 0.1 liter chamber is used for environmental radiation monitoring. The rigid and compact construction makes the chamber suitable for stationary radiation monitoring as well as for mobile operation in vehicles. The chamber is designed to measure very high dose rates of up to 4000 Sv/h (90 % saturation) as they may occur after nuclear accidents. Since the sensitive volume is open to the surroundings, air density correction is required for precise measurement. The chamber is fully guarded up to the sensitive volume. The cylindrical chamber is made of aluminum with 4 mm wall thickness. The ion-collecting electrode is made of aluminum too. The external chamber diameter is 60 mm and the length is approx. 150 mm. For the transfer of the measuring signal and the polarizing voltage, the chamber is supplied with two coaxial Fischer connectors. Via an optional adapter cable of 1.5 m length, the chamber can be connected to a dosemeter with M connector, which has input circuits on ground potential.

Specifications

Type of product vented cylindrical ionization chamber
Application radiation monitoring
Measuring quantity

photon equivalent dose

Nominal sensitive volume 102 cm3
Design not waterproof, vented
Reference point

chamber center

Direction of incidence radial
Nominal response

3 µC/Sv

Chamber voltage 500 V nominal
Energy response ≤ ± 10 % (Ephoton 80 keV)

Directional response in air ≤ ± 10 % for tilting perpendicular to the axis up to ± 20°

Leakage current ≤ ± 50 fA

Materials and measures

Wall of sensitive volume 4 mm Al,
2.85 g/cm3
Total wall area density 1.14 g/cm2
Dimension of sensitive volume radius 22.5 mm

length 88 mm

Central electrode Al, diameter 25 mm
Outer dimensions diameter 60 mm
length 150 mm

Ion collection efficiency at nominal voltage

Ion collection time 1.3 ms
Max. dose rate for
≥ 99 % saturation
≥ 90 % saturation

355 Sv/h
3550 Sv/h

Useful Ranges

Radiation quality 80 keV … 1.3 MeV
Temperature

(10 … 40) °C
(50 … 104) °F

Humidity (10 … 80) %, max 20 g/m3
Air pressure (700 … 1060) hPa

Options

T7262/U10-1.5 Connection cable with M connector, length 1.5 m

Parts

T32001 Radiation monitoring chamber 0.1 l, Fischer coax connectors