100cm2 Beta/Gamma Scintillation Probe

The Model 190-100BGS is a large area scintillation detector suitable for measurement of beta particles and low energy gamma radiation.

100cm2 Beta/Gamma Scintillation Probe
 
  • Features
  • Specifications
  • Image Gallery

Features

The Model 190-100BGS is a large area scintillation detector suitable for measurement of beta particles and low energy gamma radiation.

The probe has high efficiencies for key isotopes used in the nuclear medicine field. This detector, coupled with the ASM-990, makes a particularly effective measurement solution.

Applications
The Model 190-100BGS is designed to measure isotopes that are typically found in hospital nuclear medicine departments, radiopharmaceutical production facilities, and environmental surveying applications where large surface area Beta/Gamma detectors are required.

Specifications

Type: NaI (TI) Pancake, scintillator optically coupled to PMT

Radiation detected:
Gamma and x-ray above 25 keV, beta above 100 keV

Applications:

  • Beta, gama frisker for nuclear medicine is 10 times more sensitive than GM probe
  • Environmental surveys

Typical background (CPM):
3000

Nominal sensitivity :
650 CPM / µR / hr 137Cs

Wall material:
0.04 in AI, 1 mm thick

Window:
130 mg/cm2 Plastic

Sensitive area:
59.2 cm2

Crystal dim.:
5.1 cm x 5.1 cm x 1.3 cm (2 in x 2 in x 0.5 in)

Probe diameter:
5.7 cm x 1.8 cm (2.25 in x 0.69 in)

Probe length:
28 cm (11 in)

Cable length:
122 cm (48 in)

Operating voltage:
900 V

Calibration:
Sensitivity to 99mTc

Cal. Tolerance:
± 10%

Efficiency:
90 Sr 5%,
137Cs 11%,
133Ba 34%,
60Co 16%

Humidity range:
0 to 95%

Operating temp:
- 40° to + 120°F; – 40° to + 50°C; Max. temp increase of 20°F/hr

Weight (approx.):
0.78 lb (0.35 kg)

Product Number: 190-100BGS

Image Gallery

Click on a thumbnail below to view full size.

  • Default Image

Posted in Fluke | Tagged detector, probe, scintillation

« Previous Next »
  • Manufacturers
  • Technologies

Featured Manufacturers

  • Biodex
  • Bionix
  • Capintec
  • Diacor
  • Exini
  • Fluke
  • International Specialty Products
  • IZI Medical Products
  • Mediso
  • PTW
  • Topex
  • Unfors
  • Vision RT
  • View all...

Technologies

  • Nuclear Medicine
  • Radiology
  • Radiation Therapy

Copyright © 2012 Harpell Associates Inc..

  • Home
  • About
  • News
  • Contact