Features
Spot Markers
Our Spot Markers are 1" in diameter by 0.25" and made of clear acrylic. The activity is supplied as a nominal value of ±15%. NIST traceable calibrations with accuracies of ±5% are available. A wooden storage box is also available (upon request).
If the activities above do not meet your specific requirements, give Capintec a call; other activities are available upon request.
Rigid Ruler
The Capintec Rigid Ruler is a plastic tube 0.197" (5.0 mm) in diameter, containing 15 sequential 0.394" (10.0 mm) sections of Co-57 and inactive lead. The overall length of the ruler is 6.7" (17 cm) with an active length of 5.91" (15.0 cm). Contained activity is supplied as a nominal value ±15%. The standard Capintec Rigid Ruler contains 140 µCi (0.74 MBq) of Co-57. Other activities are available upon request.
Penpoint Markers
The Penpoint Marker is used in tracing the outlines of anatomical features on a patient. The trace appears almost instantly on the gamma camera display. Capintec’s Penpoint Markers contain 100 µCi of Co-57 in a bead at the end of an anodized aluminum rod. The pen-shaped rod screws into a brass cap which shields the active point.
Flexible Marker
Flexible Markers are useful in outlining anatomical parts or borders of organs on patients. Co-57 is uniformly dispersed in an epoxy matrix and contained in a 2.4 mm flexible plastic tube. The overall and active length of the marker is 19.7" (50 cm).
Flexible Rulers
The Capintec Flexible Ruler is a plastic tube 0.19" (4.8 mm) in diameter, containing 45 sequential 0.394" (10.0 mm) sections of Co-57 and inactive lead. The overall length of the ruler is 18.5" (47 cm), with an active length of 17.7" (45 cm). Contained activity is supplied as a nominal value ±15%. The standard Capintec Flexible Ruler contains 20 µCi (0.74 MBq) of Co-57. Other activities are available upon request.
“L” and “R” Spot Markers
In order to better mark the orientation of the patient, these spot markers containing 100 µCi of Co-57 identify the Left side and/or the Right side of the patient. The “L” and “R” are clearly identified on the patients film.
Specifications
| Item # | Description | µCi | |
|---|---|---|---|
| 0975-S010 | Spot Marker | Co-57 | 10 |
| 0975-S010 | Spot Marker | Co-57 | 10 |
| 0975-S025 | Spot Marker | Co-57 | 25 |
| 0975-S050 | Spot Marker | Co-57 | 50 |
| 0975-S100 | Spot Marker | Co-57 | 100 |
| 0975-S200 | Spot Marker | Co-57 | 200 |
| 0975-8030 | Spot Marker | Au-195 | 30 |
| 0975-P054 | Pen Marker | Co-57 | 100 |
| 0975-F050 | Flex Marker | Co-57 | 50 |
| 0975-F150 | Flex Marker | Co-57 | 150 |
| 0975-0283 | Flex Marker (Long) | Co-57 | 3 |
| 0975-FR57 | Flex Ruler | Co-57 | 440 |
| 0975-RR57 | Rigid Ruler | Co-57 | 140 |
| 0975-8004 | Radioactive Ruler | Co-57 | 160 |
| 0975-8005 | Flex Ruler | Co-57 | 460 |
| 0975-0260* | Radioactive Pointer | Co-57 | 50 |
Other activities are available upon request.
Produced three times per year. Order by Feb. 1st, June 1st, or Oct. 1st.
Image Gallery