Markers and Rulers

Spot Markers are 1" in diameter by 0.25" and made of clear acrylic.

Markers and Rulers
 

Features

Spot Markers

Our Spot Markers are 1" in diameter by 0.25" and made of clear acrylic. The activity is supplied as a nominal value of ±15%. NIST traceable calibrations with accuracies of ±5% are available. A wooden storage box is also available (upon request).

If the activities above do not meet your specific requirements, give Capintec a call; other activities are available upon request.

Rigid Ruler

The Capintec Rigid Ruler is a plastic tube 0.197" (5.0 mm) in diameter, containing 15 sequential 0.394" (10.0 mm) sections of Co-57 and inactive lead. The overall length of the ruler is 6.7" (17 cm) with an active length of 5.91" (15.0 cm). Contained activity is supplied as a nominal value ±15%. The standard Capintec Rigid Ruler contains 140 µCi (0.74 MBq) of Co-57. Other activities are available upon request.

Penpoint Markers

The Penpoint Marker is used in tracing the outlines of anatomical features on a patient. The trace appears almost instantly on the gamma camera display. Capintec’s Penpoint Markers contain 100 µCi of Co-57 in a bead at the end of an anodized aluminum rod. The pen-shaped rod screws into a brass cap which shields the active point.

Flexible Marker

Flexible Markers are useful in outlining anatomical parts or borders of organs on patients. Co-57 is uniformly dispersed in an epoxy matrix and contained in a 2.4 mm flexible plastic tube. The overall and active length of the marker is 19.7" (50 cm).

Flexible Rulers

The Capintec Flexible Ruler is a plastic tube 0.19" (4.8 mm) in diameter, containing 45 sequential 0.394" (10.0 mm) sections of Co-57 and inactive lead. The overall length of the ruler is 18.5" (47 cm), with an active length of 17.7" (45 cm). Contained activity is supplied as a nominal value ±15%. The standard Capintec Flexible Ruler contains 20 µCi (0.74 MBq) of Co-57. Other activities are available upon request.

“L” and “R” Spot Markers

In order to better mark the orientation of the patient, these spot markers containing 100 µCi of Co-57 identify the Left side and/or the Right side of the patient. The “L” and “R” are clearly identified on the patients film.

Specifications

Item # Description   µCi
0975-S010 Spot Marker Co-57 10
0975-S010 Spot Marker Co-57 10
0975-S025 Spot Marker Co-57 25
0975-S050 Spot Marker Co-57 50
0975-S100 Spot Marker Co-57 100
0975-S200 Spot Marker Co-57 200
0975-8030 Spot Marker Au-195 30
0975-P054 Pen Marker Co-57 100
0975-F050 Flex Marker Co-57 50
0975-F150 Flex Marker Co-57 150
0975-0283 Flex Marker (Long) Co-57 3
0975-FR57 Flex Ruler Co-57 440
0975-RR57 Rigid Ruler Co-57 140
0975-8004 Radioactive Ruler Co-57 160
0975-8005 Flex Ruler Co-57 460
0975-0260* Radioactive Pointer Co-57 50

Other activities are available upon request.

Produced three times per year. Order by Feb. 1st, June 1st, or Oct. 1st.

Image Gallery